CSR Hebel Construction Notes

General Notes

    • These notes and details are to be read in conjunction with the project’s contract documentation.
    • All materials and workmanship shall be in accordance with this Installation Guide, the current edition of the Hebel® Technical Manual and other Hebel® documentation.
    • Refer to architectural drawings for all setting out dimensions.
    • Do not scale drawings, use written dimensions.
    • Should any omission, penetration, cutting of panels, discrepancy or fault exist, contact the designer immediately for a decision before proceeding with work.
    • All load-bearing walls, bearing on Hebel® floor panels, shall be supported separately in accordance with the project engineer’s design.
    • Hebel® accepts no responsibility for the design or selection of supporting walls, lintels, beams, columns or other structural members.
    • Corrosion protection of all structural steelworks shall be specified by the project engineer or architect.
    • The temporary restraint of walls is the responsibility of the builder or installer.
    • PowerBlocks on site should be protected against rain and water saturation. This can best be achieved by leaving the shrink-wrap cap on the top of pallets and covering the top of blockwork if rain threatens. PowerBlocks should not be laid in the rain.

IMPORTANT

  • Ensure engineering tie-down rods are present and located in accordance with the engineer’s documentation.
  • Ensure control joint locations are marked out in accordance with the engineering documentation.

 Coatings

Table 9.1 details Hebel recommendations for Coating System options for Low Rise and Detached Residential construction to deliver a durable, monolithic appearance.
Hebel and Dulux Acratex have developed coating systems designed specifically for the Hebel AAC substrate and warrant these systems for 7 years. Performance requirements for alternate system options are provided. In such circumstances, the project specifier must satisfy themselves that systems are engineered and suitable for relevant project requirements.
General purpose, site or pre-bagged sand and cement renders must not be used on Hebel PowerBlock™ walls, owing to potential variability and unsuitability of formulation for Autoclaved Aerated Concrete (AAC).

Conventional exterior low build paint systems must not be used, as their ability to accommodate normal expansion and contraction in order to maintain a crack free protective layer is not assured.

Refer to “High Performance Coating Systems” brochure on the website, for more information.

Reinforcing Mesh Installation

Fully meshing all rendered Hebel surfaces using alkali-resistant glassfibre mesh is recommended to assist in maintaining render integrity and minimising consequential cracking.
The minimum requirement is to mesh at corners of wall openings (doors and windows) to minimise corner cracking. The mesh should be embedded into the wet first pass of Hebel
HighBuild.

Linings

Plasterboard can be direct fixed to internal Hebel PowerBlock™ walls. It is recommended that battens be used behind plasterboard linings on the inside surface of external walls. Fibre
Cement sheet linings must be installed on battens.

Table 9.1 Coating systems for Hebel PowerBlock

Primer Acrylic Texture Body Coat Finish Coats
Hebel
Product
Finish
Style
Surface
Aignment
Base
Render or
Levelling
Coat
Product
Description &
Performance
Guide
Dulux
AcraTex
Specification
Product
Description &
Performance
Guide
Dulux
AcraTex
Specification
Product
Description &
Performance
Guide
Dulux
AcraTex
Specification
Comment
PowerBlock Uniform
Sand
Texture
profile
≤3mm Hebel
HighBuild™
(Render)
Relevant to
coatings supplier
recommendations
AcraPrime
501/1
OPTION 1:
1-2mm Acrylic
Texture
Trowel applied
Type: AS4548.4
Polymercontent (dry):
9% min.
Tuscany
orCoventry
Coarse
Elastomeric
Membrane
Type:
AS4548.1
Min DFT:
150 micron
AcraShield
Matt
or
Elastomeric
201
2nd coat
Elastomeric
Membrane
recommended
dependant on
project
complexity
eg. unbroken
broadwall,
scaffolding or
cutting in detail
and coastal areas.
OPTION 2:
Dependant on specifier
approval:
Sponge finishing of Hebel
HighBuild™ to a project
approved standard; plus
Elastomeric Membrane
finishing system.
Elastomeric
Membrane
Type:
AS4548.1
Min. DFT:
250 micron
Elastomeric
201
Hebel
recommends the
installation of
1-2mm Acrylic
Texture Coat over
the render base
coat providing
improved
consistency of
finish, system
flexibility and
durability.

find out more