DURAGRID FACADE SYSTEMS RESIDENTIAL

THE DURAGRID FACADE SYSTEM UTILISES BGC FIBRE CEMENT SHEETING, OFFERING THE IDEAL SOLUTION FOR CLADDING THE EXTERIOR OF LOW TO MEDIUM RISE HOMES. DURAGRID GIVES BUILDINGS A MODERN AND EXTREMELY DURABLE FINISH.

DURAGRIDSHEETING HAS A SMOOTH, FLAT SURFACE AND SQUARE EDGE FINISH WHICH IS SUITABLE FOR EXPRESSED JOINTING AND PROVIDES A FACADE SUITABLE FOR A NUMBER OF FINISHES – FROM PAINTED TO TEXTURED COATINGS.

THE DURAGRID FACADE SYSTEM:

  • IS LIGHTWEIGHT
  • IS HIGHLY DURABLE
  • PANELS WILL NOT ROT, BURN OR CORRODE.
  • PANELS ARE NOT AFFECTED BY TERMITES, AIR, STEAM, SALT OR SUNLIGHT.
  • CAN BE EASILY DECORATED IN A NUMBER OF DESIGN FINISHES.
  • QUICK AND SIMPLE TO INSTALL USING MANUAL NAILING, GUN NAILING OR SCREW FIXING.
APPLICATIONS
Duragrid Facade system utilises BGC fibre cement panels and graded, primed timber or steel battens to form a strong and durable facade cladding system.

BGC Duragrid is ideally suited for versatile architectural applications in domestic and multi storey residential buildings.

Duragrid panels are designed for installation in a variety of patterns, including vertical, horizontal, brick-bond or diamond inclined.

BGC Duragrid panels are available in 9mm thickness and may be finished with site applied acrylic paint systems or a factory applied high quality polyurethane plain finish. These may need alternative fixing methods. Please contact your BGC office for advice.

NOTE: The fitting of the Duragrid Facade system should only be attempted by a professional contractor. Your local BGC Fibre Cement office can provide you with a list of recommended Duragrid installers.

ADVANTAGES

  • Lightweight cladding system
  • Readily accepts many forms of decorative finish
  • Highly durable
  • Dynamic architectural style
  • Face sealed panels

ENERGY EFFICIENCY CONSIDERATIONS

Energy efficiency requirements have been introduced into the Building Code of Australia (BCA) for both commercial and residential buildings. Thermal heat transfer into and out of the building envelope will effect the running cost of the building and careful consideration of thermal heat transfer needs to be addressed by the architects, engineers and building designers.

PRODUCT INFORMATION

BGC Duragrid panels are an autoclaved, cellulose fibre reinforced silica/cement panel, specially formulated and prepared to meet the requirements for use in external applications. Duragrid panels have a smooth flat surface and a neat square edged finish, for enhanced expressed joint facades.

BGC Fibre Cement products are manufactured to the Australian / New Zealand Standard AS/NZS 2908.2-2000 Cellulose-Cement Products, Part 2: Flat sheets and Duragrid is classified as Type A Category 3.

FIRE RESISTANCE

BGC Fibre Cement 9mm has been tested for and passed the Early Fire Hazard Property criteria in compliance with AS/NZS 1530.3 and AS/NZS 3837 and is deemed a Group 1 Material in accordance with the Building Code of Australia (BCA), Volume 1, Specification A2.4; Fire Hazard Properties. AS/NZS 1530.3; Early Fire Hazard Properties.

  • Ignition Index
0
  •  Spread of Flame Index
0
  •  Heat Evolved Index
0
  •  Smoke Developed Index
0-1

DURABILITY

BGC Duragrid physical properties ensure it’s durability in exposed applications.

  • Duragrid panels are immune to permanent water damage in both short and long-term exposure.
  • Duragrid panels will not rot or burn and are unaffected by termites, air, steam, salt and sunlight.
  • Duragrid panels are not adversely affected over a temperature range of 0°C to 95°C.

Vapour permeable sarking must be installed under the timber or steel batten in ccordance with the AS/NZS 4200.2 – ‘Pliable building membranes and underlays – Installation’ and the sarking manufacturers’ guidelines. The sarking should have the following properties:

  • Vapour barrier – low or medium
  • Water barrier – high

Vapour permeable sarking is used to prevent moisture ingress by acting as a drainage plane whilst enabling water vapour build up from inside the frame to escape.

THERMAL CONDUCTIVITY

Duragrid panels have relatively low thermal conductivity: R-value. At Equilibrium Moisture content the approximate R-Value of Duragrid is;- 0.55 W/m°C.

PANEL SIZES AND MASS

Duragrid panels are available in the following sizes
THICKNESS
mm
MASS
KG/M2
WIDTH
mm
LENGTH mm
1190 1790 2390 2990
9 11.7 590 x
890 x
1190 x x

SHEET TOLERANCES

  • Width +0/-1mm
  • Length +0/-2mm
  • Thickness +10%/-0%
  • Diagonals difference (max) 2mm
  • Edge straightness deviation (max) 1mm

HANDLING AND STORAGE

BGC Duragrid must be stacked flat, up off the ground and supported on equally spaced (max 400mm) level gluts. Care should be taken to avoid damage to the ends, edges and surfaces.

  • Sheets must be kept dry. When stored outdoors it must be protected from the weather. Sheets must be dry prior
  • to fixing, jointing or finishing.

COASTAL AREAS

The durability of galvanised nails and screws used for external cladding in coastal or similar corrosive environments can be as low as 10 years.

For this reason BGC recommend the use of stainless steel fasteners within 1km of the coast or other large expanses of salt water.

ACCESSORIES AVAILABLE FROM BGC

DURABATTEN-PRIMED, GRADED TIMBER 19 x 70 x 3000mm  
19 x 70 x 2700mm
HORIZONTAL BACKING STRIP 1190mm  
2390mm
2990mm
CAVITY VENT STRIP uPVC  
19 x 2700mm
SEALANT Sika 11FC or similar  
COUNTER SINKER Countersinking Tool  
Tungsten Carbide

FASTENERS

DURABATTEN TO FRAME

DURABATTEN TIMBER TO TIMBER FRAME
Class 3 Corrosion resistant Ring shank nail – 2.8 x 65mm

DURABATTEN TIMBER TO STEEL FRAME
Builders Class 3, 8 x 35mm Wingtek Self Embedding Head Screw, 8 x 40mm Wingtek Self Embedding Head Screw

DURABATTEN STEEL TO STEEL FRAME
Class 3 Hex Head Screw, 12-14 x 20mm

DURAGRIDT TO DURABATTEN

DURAGRID DURABATTEN TIMBER
C25 304 Stainless Steel Brads

2.8 x 30mm Fibre Cement nail

8 x 10 x 25mm Class 3 Countersunk wood screw

DURAGRID TO DURABATTEN STEEL
No.8 x 30mm Countersunk self drilling

FASTENERS

Select fasteners with suitable durability for the prevailing conditions. Please consult your supplier for:

  • Minimum requirements Class 3
  • Stainless steel may be required in some applications

All screw holes must be filled with an epoxy sealer such as Megapoxy P1, Hilti CA125 or Hilti CA273 and sanded flush to provide a flat surface for finish coating.

PRE COUNTERSINK

When using screws to fasten Duragrid, pre countersinking is required so that the fastener is 2mm under the sheet surface for filling with Epoxy filler.

DESIGN CONSIDERATIONS

The designer should determine the wind pressure for the project and specify the layout, spacing and fixing of the Durabatten to the structure.

The deflection of the supporting structure should be limited to span/250 for Serviceability Wind Load, or as limited by AS/NZS1170.

In areas where there is a probability of wind loading, care should be taken in the design detailing, especially around all openings, corners and other junctions, to ensure the weather resistance of the total system.

Before the Duragrid panels and the supporting substructure are installed, particular care should be taken to ensure that all flashing and waterproofing work is complete, including all vapour permeable building wraps and damp proof coursing.

CONTROL JOINTS

In many cases, control joints will not be required as typical expressed joints permit some differential movement of the Duragrid panels and the sub-framing.

It is recommended that the designer consider the need for control joints in the following cases:

  • Where Duragrid crosses a building control joint.
  • Where there is likelihood of movement in the sub-framing.
  • Continuous lengths greater than 8 metres in length.
  • At a change in the structural substrate; eg masonry to steel framing.

Structural movement vertical and horizontal control joints are required to match existing structural control joints and should pass through the facade.

GROUND CLEARANCE

Maintain a minimum 150mm clearance to earth or as required by local building regulations.

GROUND CLEARANCE & FOUNDATION DETAIL

PANEL PREPARATION

For insitu paint finish applications, Duragrid panels are supplied sealed with a proprietary sealer applied during manufacture for durability.

Where it is necessary to cut sheets, cutting tools should have a dust extraction system.

Cut edges must be sealed with BGC Edge Sealer or an acrylic coating to eliminate moisture absorption.

A saw blade such as BGC Durablade with a poly crystalline diamond tip specifically designed to cut fibre cement sheets is recommended.

Ensure work area is well ventilated and wear an approved dust mask (AS/NZS1715 and AS/NZS1716) and safety glasses (AS/NZS1337).

BACKING STRIP INSTALLATION & SEALING

At the horizontal joints between the Duragrid panels, the Horizontal Backing Strip should be bonded to the back of the Duragrid panel to form a socket to which the Duragrid panels
above are fixed over.

Set the backing strip 2mm from the edge of the Duragrid panel. Seal the cut edge with BGC Edge Sealer.

The backing strip can be fixed using:

  • SIKA 11FC. Ensure that the sealant has cured fully before panel installation.
  • 3m 12.7mm VHB4901 double sided tape.

The contact surfaces to be cleaned with 3M HIPA 300 Adhesive cleaner.

NOTE: SIKA 11FC is the preferred option for fixing the backing strip.

NOTE: Ensure the sealant fills the void in the back of the Horizontal Backing Strip to prevent moisture ingress.

SEALANT (Preferred Option for Optimal Adhesion and Sealing ) – FRONT VIEW

BACKING STRIP TAPE – FRONT VIEW

BACKING STRIP SEALANT – REAR VIEW 

FASTENER SPACING – RESIDENTIAL

FIXING DURAGRID TO DURABATTEN
Fix cladding to batten via a continuous 6mm bead of SIKAFLEX 11FC polyurethane adhesive to all contact surfaces and brad nails at 200 centres.

FIXING DURABATTEN TO TIMBER WALL FRAMES
Spans should be approximately equal (within 25%)
Battens can be installed either ON stud (batten fixed directly to stud) or OFF stud (batten fixed to noggin)
Where battens are fixed OFF stud, noggins are to be evenly spaced with maximum centres of 800mm.
Fix timber batten to timber wall frame with:

ON-stud
1Nº 65 x 2.87 Ring Shank nails @ 300 centres.

OFF-stud
Fix timber battens to noggins with:

1 x 65 x 2.87 Ring Shank nails.
C1 (max 1.61kN pullout load)
Fix timber battens to noggins with:
1 x 65 x 2.87 Ring Shank nails. Or: 8-15 x 40mm screws.

FIXING TIMBER NOGGINS TO TIMBER STUDS
Where noggins support battens, noggins must be securely fixed to studs.
Noggins should not be spaced more than 800mm.

N1-N3
Fix noggins to studs via minimum 2Nº ø3.75 nails at each end.

BATTEN SPAN/WIND PRESSURE LOAD

Wind
 Classification
 AS4005
Durabatten
 Off Stud
 Fix
Durabatten
& Stud
Spacing
Durabatten Fixing Centres Durabatten Span Duragrid Fixing Centres
N1, N2, N3 OK 600 300 850 200
N4, N5 No 450 200 n/a 200
N6 No 300 200 n/a 150
C1 OK 450 200 800 200
C2 No 450 200 n/a 200
C3 No 450 200 n/a 200
C4 No 300 200 n/a 150

NOTE: Durabatten can be fixed off stud in N1, N2, N3, C1 wind classification areas.

Duragrid can be fixed with C25 304 stainless brads and SIKA 11FC as specified in N1, N2, N3, C1, C2 locations.

Duragrid should be screw fixed in other locations.

FRAMING

Ensure that the frame is square and work from a central datum line. The frame must be straight and true to provide a flush face to receive the panels.

BGC recommend a maximum tolerance of 3mm-4mm in any 3000mm length of frame. Duragrid will not straighten excessively warped or distorted frames and any warping may still be visible after Duragrid is applied.

FRAME STRAIGHTNESS

Durabatten can be fixed on stud or off stud –
Refer to Span Table 1. Off stud fixing is restricted to low wind areas and noggings are required at maximum 800mm centres – Refer to span tables in all instances.

The vertical expressed joins must coincide with the centre line of the Durabatten. Stud centres may have to be designed to coincide with express joins.

TIMBER FRAME
Use of a timber frame must be in accordance with AS1684
Residential timber-framed construction and the framing manufacturers’ specifications.

Use only seasoned timber. Do not use unseasoned timber as it is prone to shrinkage and can cause sheets and frames to move up.

“Timber used for house construction must have the level of durability appropriate for the relevant climate and expected service life conditions including exposure to insect attacks or
to moisture which could cause decay” – Reference AS 1684.2

Stud framing members must be a minimum of 70x35mm.

DURABATTEN INSTALLATION TO TIMBER

TIMBER DURABATTEN
Install over Timber Durabatten either off stud or on stud.

ON STUD

OFF STUD

BATTEN JOINING

INSTALLATION DETAILS

The architectural intent and details of buildings vary from one designer to the next, and the variety of details would be impossible to catalogue.

The detail diagrams following are intended to assist the designer in achieving a high quality weather resistant facade.

The designer should not digress from the specification set out in this manual.

PANEL POSITION – FRONT VIEW

Use the backing strip as a temporary gauge to space the vertical joint of successive boards ensuring a uniform 10mm space between successive panels.

INSTALLATION DETAILS

PANEL INSTALLATION

TYPICAL SEALANT APPLICATION

FASTENER SPACING

Duragrid panels are to be fixed with a continuous 6mm bead of SIKA 11FC or similar polyurethane sealant/adhesive to all contact surfaces with required fasteners at specific centres.

Duragrid panels should be sealed and fixed 1 panel at a time. Only apply sealant to the contact surfaces of the next panel to be fixed.

SOFFIT DETAIL

FOUNDATION DETAIL

INTERNAL CORNER DETAIL

EXTERNAL CORNER DETAIL

FASTENER POSITION

ENCLOSED BALUSTRADE/PARAPET WALL

PENETRATIONS, WINDOW & DOOR OPENINGS

There are numerous varieties of penetrations, openings, and windows and door treatments available, and each weather proofing detail will be dependent on the material, style and manufacturer’s specifications.

Adequate weather proofing of the opening application must be considered by the building designer, in conjunction with the penetration, window and door manufacturer.

The following diagrams are a guide only and the designer should consult with the appropriate manufacturers for the detail design to ensure adequate weather proofing.

WINDOW JAMB

WINDOW HEAD

WINDOW SILL

THERMAL BREAKS

Thermal breaks are required for steel framed buildings, in walls enclosing habitable and or usable spaces. Careful consideration of thermal heat transfer and the position of thermal breaks need to be addressed by the architects, engineers and building designers.

Thermal breaks should be installed between the steel Durabatten sections and the Duragrid cladding.

Balustrades, parapets, and other non-enclosing wall elements may not require thermal bridging, except where the possibility of high thermal heat transfer exists through the steel CFS sections to the main structural steel element of the building.

MOISTURE MANAGEMENT
Designers, specifiers and builders have a duty of care to identify moisture-associated risks with any individual building design.

Wall construction design should consider both the interior and exterior environments of the building to effectively manage moisture. Special consideration should be given to buildings that are in extreme climates or at higher risk of wind driven rain.

In addition, all wall openings, penetrations, junctions, connections, window heads, sills and jambs must incorporate appropriate flashing for waterproofing. All other components, materials and installation methods used to manage moisture in walls should comply with the relevant standards of the Building Code of Australia (BCA).

WARRANTY

BGC warrants its products to be free from defects caused by faulty manufacture or materials. If any of its products are so defective the Company will at its option, repair or replace them, supply equivalent replacement products or reimburse the purchase price.

This warranty shall not apply to any loss or consequential loss suffered through or resulting from defects caused by faulty manufacture or materials.

Fittings or accessories supplied by third parties are beyond the control of BGC and as such is not warranted by BGC.

Find Out More