CSR Hebel Energy Efficiency

Table 3.1 shows a number of different external wall configurations and identifies which satisfy the BCA requirement for Climate Zones 1 to 8. Table 3.2 lists the component R-Values used as a basis for Table 3.1. For more information on Hebel and energy efficiency refer to Section 3 and Appendix C and D of the Hebel Technical Manual.

Table 3.1:  BCA Energy Efficiency Compliance.

Wall Configuration Satisfies BCA Requirements
Climate Zone: 1* 2* 3* 4 5 6 7 8
Class 1 & Class 10a Minimum R-Value: 1.4 1.4 1.4 2.2 1.9 2.2 2.4 3.3
   1. 250mm Block Only Y Y Y N Y N N N
   2. 250mm Block + 25mm Cavity Y Y Y Y Y Y N N
   3. 250mm Block + 25mm Cavity + Sarkin Y Y Y Y Y Y Y N
   4. 250mm Block + 25mm Cavity + 75mm PowerPane Y Y Y Y Y Y Y N
   5. 250mm Block + 40mm Cavity + R1.0 InsulatioN Y Y Y Y Y Y Y N
   6. 250mm Block + 25mm Cavity + Double Sided RFL + 25mm Cavit Y Y Y Y Y Y Y Y
   7. 250mm Block + 90mm Cavity + R2.0 InsulatioN Y Y Y Y Y Y Y Y

*Note: For elevated ground floor slabs an R-Value of 1.9 is required.

Table 3.2:  Wall Element R-Value.

System Number Construction Overall Thickness R-Value Rw Rw
+ C
tr
401 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
10mm Gyprock
268 mm 2.1 48 43
402 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres
10mm Gyprock
296mm 2.3 51 43
403 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres
Non reflective (normal sarking)
10mm Gyprock
296mm 2.3 51 43
404 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres
Reflective foil
10mm Gyprock
296mm 2.6 51 43
405 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres with 50mm 11kg – Bradford Glasswool
Non reflective (sarking)
10mm Gyprock
296mm 3.1 53 44
406 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
8mm Render in Texture Coat and Paint
216mm 2.1 48 43

find out more

Jan 09

CSR Hebel System Components

Products

Hebel stocks many of the products and materials required to construct your Hebel home.

Product Description Product Description
  Hebel Thermoblocks
50mm – 300mm (25mm
increments).
  Hebel Adhesive
20 kg bag
Used for gluing the blocks
together at vertical and
horizontal joints.
  Sill blocks
600x200x50mm thick or
100mm thick, 30º slope.
  PowerFloor
Panels
1800mm x 600mm x 75mm
  Hebel Mortar
20 kg bag
Used as thick bed mortar base
to provide a level base for the
first course.
  Custom PowerFloor
Panels
150mm – 250mm x 600mm
by up to 6m
  Hebel Lintels
To suit openings up to 5m
  Hebel HighBuild render
20kg bag
Used as a preparation coat
to level surface providing an
even true surface.
  Stair treads
300mm x 175mm x 1m
or 1.2m
  Control joint tie
Used at every third
course in control joints.
  Hebel Patch
10kg bag
Used to prepare minor chips
or damage to blocks.
  Sliding joint tie
Fixed to RHS/SHS column
every second course.
  Corrosion Protection Paint
To coat exposed
reinforcement during cutting.

find out more

Jan 09

CSR Hebel Delivery and Storage

PowerBlock  Delivery

PowerBlock pallets should be unloaded and moved with only approved lifting devices. Before use, the lifting devices should be checked for the required lifting tags. PowerBlock pallets should be unloaded and stored as close to the intended installation area as possible. This will increase work efficiency and minimise the need for secondary lifting.

It is good practice to inspect the delivery for damaged blocks. Unnecessary handling will increase the risk of damage to the Hebel® PowerBlocks.

Care should be taken when cutting the packaging straps, blocks may come away and cause injury or become damaged.

TIP – When a block is damaged it may be possible to cut away the damaged section and use the remaining portion in the wall.

Storage

All materials must be kept dry and preferably stored undercover. Hebel® PowerBlocks should be left on their pallet until they are required. Place the pallet on a level and stable surface. The project engineer should be consulted as to the adequacy of the structure to support Hebel® PowerBlocks if they are not stored directly on the ground or concrete slab.

find out more